Model :2001
Type: Single-channel TCD analyzer
Accuracy: 0.01% (0.1% for H2S)
Sample Type: Gas
Detects: O2/N2, CO2, H2S, C1–C5, C6+
Compliance: ASTM D1945, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model : 2002
Type: Single-channel TCD analyzer with 2,2-dimethylbutane backflush
Sample Type: Gas
Detects: O2/N2, Ar, CH4, H2S, C1–C5, C6+
Compliance: ASTM D1945, GPA 2261, GPA 2177, ISO 6974-5, DIN 51872-5
Model: 2003
Type: Advanced single-channel TCD analyzer
Accuracy: 0.01% (0.1% for H2S)
Detects: O2/N2, CO2, H2S, C1–C5, C6+
Compliance: ASTM D1945/D1946, GPA 2261, DIN 51872-5
Model: 2006
Type: Dual-channel TCD/FID analyzer
Accuracy: 0.01% (0.1% for H2S)
Detects: O2/N2, CO2, H2S, C1–C5, C6+
Range: Up to C10
Compliance: ASTM D1945, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model 2008
Type: Dual-channel TCD/FID analyzer with backflush
Sample Type: Gas and liquid
Range: Up to C10
Compliance: ASTM D1945/D1946, GPA 2261, DIN 51872-5
Model 2101
Type: Dual-channel TCD/TCD analyzer
Accuracy: 0.01% (0.1% for H2S)
Features: Full-range helium and hydrogen detection, 2,2-dimethylbutane backflush
Compliance: ASTM D1945, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model 2103
Type: Dual-channel TCD/TCD analyzer
Carrier Gases: Helium/Nitrogen
Compliance: ASTM D1945/D1946, GPA 2261, DIN 51872-5
Model 2106
Type: Triple-channel TCD/TCD/FID analyzer
Accuracy: 0.01% (0.001% on FID)
Detects: O2/N2, CO2, C1–C5, C6+
Compliance: ASTM D1945, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model 2108
Type: Triple-channel TCD/TCD/FID analyzer
Carrier Gases: Helium/Nitrogen
Accuracy: 0.01% (0.001% on FID)
Compliance: ASTM D1945/D1946, IP 345, GPA 2286, ISO 6974E, 6974-3, 6975
Model 2108H2
Type: Triple-channel TCD/TCD/FID analyzer
Carrier Gases: Hydrogen/Nitrogen
Accuracy: 0.01% (0.001% on FID)
Compliance: ASTM D1945/D1946, IP 345, GPA 2286, ISO 6974E, 6974-3, 6975
Model 2201
Type: Single-channel TCD analyzer
Sample Types: Gas, liquid, and pressurized gas
Accuracy: 0.01% (0.1% for H2S)
Detects: O2/N2, CO2, H2S, C1–C5, C6+
Compliance: ASTM D1945, GPA 2177, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model 2203
Type: Single-channel TCD analyzer
Sample Types: Gas, liquid, and pressurized liquid
Feature: O2/N2 separation
Compliance: ASTM D1945/D1946, GPA 2261, DIN 51872-5
Model 2206
Type: Dual-channel TCD/FID analyzer
Sample Types: Gas, liquid, and pressurized gas
Range: Hydrocarbon detection up to C10
Compliance: ASTM D1945, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model 2208
Type: Dual-channel TCD/FID analyzer
Sample Types: Gas, liquid, and pressurized liquid
Accuracy: 0.01% (0.1% on TCD, 0.001% on FID)
Range: Hydrocarbons up to C10
Compliance: ASTM D1945/D1946, GPA 2261, GPA 2286, GPA 2186, DIN 51872-5
Model 2301
Type: Dual-channel TCD/TCD analyzer
Sample Types: Gas, liquid, and pressurized liquid
Features: Sample-loop purge, secondary filter, vaporization zone
Compliance: ASTM D1945, GPA 2177, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model 2303
Type: Dual-channel TCD/TCD analyzer
Sample Types: Gas, liquid, and pressurized samples
Feature: O2/N2 separation
Compliance: ASTM D1945/D1946, GPA 2261, DIN 51872-5
Model 2306
Type: Triple-channel TCD/TCD/FID analyzer
Sample Types: Gas, liquid, and pressurized liquid
Features: Sample-loop purge, secondary filter, vaporization zone
Compliance: ASTM D1945, GPA 2177, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5
Model 2406
Type: Dual-channel TCD/FID analyzer
Sample Types: Gas, liquid, and pressurized gas
Range: Hydrocarbon detection up to C10
Features: Sample-loop purge, secondary filter, vaporization zone
Compliance: ASTM D1945, GPA 2261, ISO 6568, ISO 6974-5, DIN 51872-5