    PXi/PXi touch

PXi/PXi touch

The PXi range consists of new high resolution, multi-application image analysis systems. The new design is compact, easy to use and offers full automation in the capture of chemiluminescent and fluorescent blots, visible gels and blots and even 2D gels.

Product Description

PXi/PXi Touch are available in three versions with a 4, 6 or 9 million pixel camera and suitable lens. PXi Access is available with a 6 or 9 million pixel camera and suitable lens.The high performance cameras result in the system having exceptional sensitivity. Chemiluminescence blots and faint fluorescent bands can therefore be easily imaged and captured. The PXi Touch and PXi Access have their own built-in screens and processors whereas the PXi is used with an external PC.

The PXi range can be used for a wide range of applications. A number of lighting options can be utilised including IR illumination, Red light, Blue light, Green light and the UltraSlim blue LED transilluminator. An integral 7 position filter wheel can accommodate a wide range of Syngene filters. The systems are controlled by the acclaimed GeneSys acquisition and capture software. Using its vast database, GeneSys can automatically configure PXi/PXi Touch/PXi Access to capture any type of image.

This high performance range has been designed to be able to excel at a wide range of applications and therefore makes the ideal workstation for any busy laboratory. Its sleek styling compliments any laboratory while its ease of use will attract a wide number of users working across numerous fields.

Perfection in imaging technology

  PXi 4/
PXi 4 Touch
PXi 4 EZ/
PXi 4 EZ Touch
PXi 6/
PXi 6 Touch
PXi 6 Access/
PXi 6 Access Touch
PXi 9/
PXi 9 Touch
PXi 9 Access/
PXi 9 Access Touch
Pixels (million) 4 4 6 6 9.1 9.1
A/D 16 bit 16 bit 16 bit 16 bit 16 bit 16 bit
Greyscales 65,536 65,536 65,536 65,536 65,536 65,536
Cooling Ultra peltier
cooling for extra long exposuresREGULATED
Ultra peltier
cooling for extra long exposures
REGULATED
Ultra peltier
cooling for extra long exposures
REGULATED
Ultra peltier
cooling for extra long exposures
REGULATED
Ultra peltier
cooling for extra long exposures
REGULATED
Ultra peltier
cooling for extra long exposures
REGULATED
Lens Motor driven f0.9 Motor driven zoom f1.2 Motor driven f1.4 Motor driven f0.95 Motor driven f1.4 Motor driven f0.95
Filter wheel motor driven Yes Yes Yes Yes Yes Yes
Maximum viewing area (cms) 15 x 11 18 x 13.5 13 x 10 21 x 17 13 x 10 21 x 17
Built-in processor/touch screen PXi 4 Touch only PXi 4 EZ Touch only PXi 6 Touch only PXi 6 Acess Touch only PXi 9 Touch only PXi 9 Access Touch only
Illumination            
White Epi overhead Yes Yes Yes Yes Yes Yes
Epi UV Optional Optional Optional Optional Optional Optional
Epi LEDs for fluorescence Optional Optional Optional Optional Optional Optional
Epi LED IR Optional Optional Optional Optional Optional Optional
Visible light table Optional Optional Optional Optional Optional Optional
UltraSlim blue LED transilluminator
Maximum viewing area (cms)
Optional

 

 

10 x 12

Optional

 

 

10 x 12

Optional

 

 

10 x 12

Optional

 

 

10 x 12

Optional

 

 

10 x 12

Optional

 

 

10 x 12

UV transilluminator
Maximum viewing area (cms)
Optional

 

11 x 15

Optional

 

11 x 15

Optional

 

11 x 15

Optional

 

11 x 15

Optional

 

11x 15

Optional

 

11 x 15

Dimensions            
(W x H x D cm) 36 x 60 x 55 36 x 60 x 55 36 x 60 x 55 36 x 60 x55 36 x 60 x 55 36 x 60 x55
Weight 31kg/37kg 31kg/37kg 31kg/37kg 31kg/37kg 31kg/37kg 31/37kg

  • Performance
    The PXi range offers superior sensitivity that is capable of imaging a wide range of applications. Image quality is superb whether you are working with chemiluminescent blots, fluorescent blots and gels, IR gels and 2D gels. With GeneSys control software no other system on the market offers this level of control. If you are looking for high quality and high performance then the PXi range is your number 1 choice.
  • High specification
    At the heart of the PXi range is a new generation of camera – 4, 6 or 9 million pixels, giving the system outstanding sensitivity. The cameras are cooled to enable longer exposures to be used which can be a necessity for chemiluminescence and for some fluorescence applications. The superior sensitivity ensures that even faint blots or gels can be imaged with the PXi/PXi Touch/PXi Access.
  • Modular
    The PXi range can use a number of different lighting options including plug and play LED modules for Red, Green, Blue and IR light. These novel lighting systems provides the user with the ability to perform coloured fluorescent, multiplex and colorimetric imaging. The new UltraSlim blue LED transilluminator provides you with the ideal solution for imaging ‘safe dyes’ and the new PXi UV transilluminator is the ideal solution for imaging stain-free gels and blots. The PXi Touch and PXi Access have their own built-in screen and processor whereas the PXi is used with an external PC.

 

Additional Information

Brand

Syngene

Sub 1

Gel Documentation Systems

Sub 2

Advanced Gel Documentation Systems